TOR Satellite
- CCS2
- CCS1
- CHadeMo
- NACS
- GB/T
A split system for large charging hubs: a central power cabinet and compact charging posts up to 100 metres away. Up to 1.3 MW per system and 8 ports — hub-scale infrastructure from a single grid connection.
Use cases
- Large charging hubs
- Logistics centres and terminals
- Bus depots
- Truck fleets
- Highway transit corridors
- Commercial vehicle depots
Key benefits
-
Up to 1.3 MW from a single connection
The central power cabinet feeds up to four charging posts — 8 ports at once. Dynamic load management routes power where it is needed, with a guaranteed minimum of 80 kW.
-
Posts up to 100 metres away
The power electronics sit separately — wherever suits the grid. Compact posts are placed around the car park independently of the cabinet.
-
Compact liquid-cooled posts
With all power electronics moved to the cabinet, a post weighs just 150 kg. Liquid cooling keeps the cables easy to handle, even at high power.
-
Built for commercial transport
Up to 1000 V output and up to 1.3 MW of system power — a solution for trucks, buses and large fleets.
-
Remote monitoring and management
Supported via OCPP, with integration into the ECOFACTOR network and third-party back-office systems.
Design and build
The charging posts have an understated, engineering-led design with a minimal footprint — all power electronics live in a separate cabinet. The powder-coated steel enclosures are built for round-the-clock heavy-duty operation, available in Carbon Grey, Silver or White as standard, with custom painting available in any RAL colour.

Images shown are for illustration only. The actual station may vary depending on configuration.
Order a stationTechnical overview
Key specifications:
- System power:
- up to 1300 kW (min. 80 kW guaranteed per port)
- Architecture:
- Split system — power cabinet + charging posts (2 ports per post)
- Number of ports:
- 8
- Cabinet-to-post distance:
- up to 100 m
- DC output voltage:
- 150–1000 V
- Connector:
- CCS2 (5 m liquid-cooled cable)
- Dimensions:
- Cabinet 2050 × 2400 × 800 mm (800 kg), post 2000 × 800 × 500 mm (150 kg)
Connectivity and control:
- Communication: Ethernet / LTE / Wi-Fi
- Protocol: OCPP
- Management: Remote monitoring and control, OTA updates
- Post interface: 10-inch touch display, RFID ISO 14443A/B
- Payment: Contactless POS terminal (optional)
- Metering: MID-approved energy meter (on posts)
Safety and reliability
- Emergency stop button with locking mechanism on every post
- Overvoltage and overload protection
- Temperature monitoring, output current stabilisation (ripple <1 A rms)
- Compliance with international standards (IEC 61851, IEC 62196, ISO 15118)
Infrastructure integration
The system integrates seamlessly with existing charging network management platforms and mobile apps. Dynamic load management (DLM) shares power across the posts, caps peak demand and integrates with the site energy management system (EMS).
*A render is used to visualize the station on location
Manufacturing and innovation
Full development cycle
Our devices are fully developed and manufactured in-house. We control the entire process — from design through to final testing and servicing.
- R&D centre in Odesa
- In-house manufacturing
- International certification


Configurations and packages
TOR Satellite is a split system: a central power cabinet and charging posts, with the number of posts tailored to your location. Below are examples of typical packages.
- 4 × CCS2
- 6 × CCS2
- 8 × CCS2
Need a different configuration? Contact our team — we will size the system for your location.

Find your station
Use the configurator to choose the form factor, power output, connectors and additional features. Get a personalised quote in just a few minutes.
To configurator- Free consultation
- Tailored approach